CATHODIC DISBONDMENT TESTING


The disbondment test is a simple way of assessing the effectiveness of the bond between the protective coating and the metal structure that it is designed to preserve.

Steel structures such as pipes and tanks that are submerged are usually protected by coatings bonded to its surface and by cathodic protection. Many pipelines are protected by ICCP (Impressed Current Cathodic Protection) as are large Boats and Ships. Any protective coating using this kind of protection will need to be evaluated for Cathodic Disbondment.

There are a number of International Standards that define the Disbondment test, however the use of a Reference Electrode is common to all.*

The Disbondment Test Cell is basically a transparent bottomless tube sealed onto the surface of the Pipe or tank in question. The tank is filled with Electrolyte and two electrode half cells are inserted into the tube to complete the set up. One is the counter electrode which may be Platinized Titanium, Platinum or another inert conductor. The other is the reference electrode, this may be one of three types:

Here is a Typical Set up:




Calomel (Mercury/Mercury Chloride Electrode. (Hg/HgSo4)

Copper Sulphate Reference (Cu/CuSO4)

Silver/Silver Chloride Reference (Ag/AgCl)

 

EDT manufacture and supply all types for the Cathodic Disbondment test.

*DIN Norm 30670, DIN EN ISO 15711, ISO 21809 Part 1 Annex H, ASTM G-8, ASTM G-42.G-95.


WHAT VALUE SHOULD MY HULL POTENTIAL BE?

Quick guide on how to interpret your Hull Potential.

Read more

Related Product

Calomel Reference Electrode

Calomel Reference Electrode

A glass bodied reference electrode half-cell with a 12mm body. Calomel reference electrodes require ..

£68.00

Silver/Silver Chloride Reference Electrode - Ag/AgCl

Silver/Silver Chloride Reference Electrode - Ag/AgCl

A glass bodied reference electrode half-cell with a 12mm body. Silver/Silver Chloride reference elec..

£68.00